Researchers at Paderborn University Are Taking Photon Counting Beyond Individual Photons

Technology

November 12, 2026 -- Scientists at Paderborn University have developed a new approach using commercial single-photon detectors that enables more than 9,000 individual photons to be counted in a single light pulse – previously, the limit was 8. This breakthrough opens up new possibilities for studying quantum light on a large scale and carrying out precise optical measurements. The findings were published today in the renowned open-access journal “Optica”.

“The more photons that need to be counted, the more difficult it becomes to detect them,” says Dr. Timon Schapeler from the Department of Physics and the Institute for Photonic Quantum Systems at Paderborn University. “Our approach extends photon counting and thus bridges the gap between single-photon measurements and highly sensitive optical power measurement devices,” Dr. Schapeler continues. To achieve this, the researchers have developed a detection system that combines superconducting nanowire single-photon detectors (SNSPDs) with a technique known as multiplexing. In this process, a light pulse is split into many smaller light pulses. This creates 1,024 detection channels, enabling precise photon counting.

Using this approach, combined with a model-based characterisation of each detection channel, the team has measured light pulses containing up to 276 photons with a measurement uncertainty of less than one photon. By way of comparison, a conventional multiplexing system would require around 37,000 detector elements to achieve the same level of precision.

“The large-scale measurement of individual photons is a key foundation of photonic quantum computing and single-photon imaging,” explains Prof. Dr. Tim Bartley, also from Paderborn University. “With this new macroscopic photon-counting technology, we can learn a great deal about how photonic quantum computers and single-photon-sensitive cameras can be scaled up.”

Scaling single-photon detection

As photonic quantum systems grow in size, it is becoming increasingly important to develop sufficiently large detection systems. However, building detectors capable of distinguishing large numbers of individual photons is extremely challenging. Conventional single-photon detectors generally only distinguish whether photons are present or not, but not their number. Photodiodes and other detectors that are sensitive to large numbers of photons, on the other hand, exhibit significant electrical noise, which makes it difficult to resolve the photon count.

Photon-counting detectors, including SNSPDs, can distinguish between different numbers of incoming photons and are known for their high efficiency, very high temporal resolution, and low noise. “We wanted to find out how far the number of photons that can be counted using SNSPDs can be increased,” says Dr. Schapeler. “This led to the development of a detector system that utilises multiplexing and the intrinsic photon-counting resolution of SNSPDs. Although both technologies had already been studied individually, their combined use on this scale had not previously been demonstrated. The system is an order of magnitude larger than earlier multiplexed single-photon counting systems.”

Multiplexing makes it possible to achieve photon counting resolution using many individual detector elements. For the new study, the researchers used multiplexing to split a light pulse into 128 smaller, time-staggered pulses. They then distributed these further across eight different detectors. This resulted in 1,024 smaller pulses, across which the original photon count was distributed. “Our approach uses low-loss optical components to distribute the light evenly across 1,024 detection channels whilst preserving the information about the photon count in each channel,” says Prof. Bartley. “This enables precise measurements, whilst multiplexing expands the range of photon counts that the system can measure.”

Precision down to a single photon

Another crucial prerequisite for high-precision photon measurements was a detector model that the researchers had previously developed in collaboration with Dr. Mariia Sidorova from the Physikalisch-Technische Bundesanstalt (PTB) in Germany. The model describes every single detector element that makes up the overall system.

To test the new approach, the researchers directed laser pulses averaging between 1 and 15,000 photons per pulse at their device. This enabled them to investigate how the detector responds under various conditions and with what precision it can determine the photon count of a laser pulse.

Thanks to the accuracy of their model, the researchers were able to demonstrate that up to 276 photons can be counted with a measurement uncertainty of less than one photon. They also showed that the detector can count more than 9,000 individual photons, albeit with increased measurement uncertainty.

In the current study, the researchers used SNSPDs exclusively to measure laser pulses. In future, they intend to apply the detectors to quantum states of light as well. This could enable the identification of quantum effects on a large scale.